IBM Flex System p270 Compute Node Installation And Service Manual page 177

Table of Contents

Advertisement

B7001733
Explanation: System firmware failure. The startup will not continue.
Response: Look for and correct B1xxxxxx errors. If there are no serviceable B1xxxxxx errors, or if correcting the
errors does not correct the problem, contact IBM support to reset the server firmware settings.
Attention: Resetting the server firmware settings results in the loss of all of the partition data that is stored on the
service processor. Before continuing with this operation, manually record all settings that you intend to preserve.
The service processor reboots after IBM Support resets the server firmware settings.
If the problem persists, Replace the system-board, as described in Replacing the system-board and chassis assembly.
B700173A
Explanation: A VPD collection overflow occurred.
Response:
1. Look for and resolve other errors.
2. If there are no other errors:
a. Update the firmware to the current level, as described in Updating the firmware.
b. You might also have to update the Management Module firmware to a compatible level.
B700173B
Explanation: A system firmware failure occurred during VPD collection.
Response: Look for and correct other B1xxxxxx errors.
B7004091
Explanation: Informational system log entry only.
Response: No corrective action is required.
B7004400
Explanation: There is a platform dump to collect
Response:
1. Collect the platform dump information.
2. Go to Isolating firmware problems.
B7004401
Explanation: System firmware failure. The system firmware detected an internal problem.
Response: Go to Isolating firmware problems.
B7001733 • B7004401
Chapter 8. Troubleshooting
165

Advertisement

Table of Contents
loading

Table of Contents