BA210001 • BA210010
BA210001
Explanation: Partition firmware reports a stack underflow was caught
Response:
1. Reboot the server.
2. Check for server firmware updates; install the updates if available.
3. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210002
Explanation: Partition firmware was ready before standout was ready
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210003
Explanation: A data storage error was caught by partition firmware
Response:
1. If the location code reported with the error points to an adapter, check for adapter firmware updates.
2. Apply any available updates.
3. Check for server firmware updates.
4. Apply any available updates.
5. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210004
Explanation: An open firmware stack-depth assert failed.
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
BA210010
Explanation: The transfer of control to the SLIC loader failed
Response:
1. Reboot the server.
2. Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware