Pr.
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for
43
reverse rotation
Second acceleration/deceleration
44
time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention operation
48
level
Second stall prevention operation
49
frequency
50
Second output frequency detection
51
Second electronic thermal O/L relay
Operation panel main monitor
52
selection
54
FM/CA terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
60
Energy saving control selection
65
Retry selection
Stall prevention operation reduction
66
starting frequency
67
Number of retries at fault occurrence
68
Retry waiting time
69
Retry count display erase
70
Parameter for manufacturer setting. Do not set.
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Fault code output selection
*6
Parameter write selection
77
Reverse rotation prevention
78
selection
*6
Operation mode selection
79
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
85
Excitation current break point
Excitation current low-speed scaling
86
factor
Speed control gain (Advanced
89
magnetic flux vector)
90
Motor constant (R1)
Downloaded from
ManualsNet.com
Name
Read Write Extended
20
21
22
23
24
25
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
36
37
38
39
3A
3B
3C
41
42
43
44
45
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
59
5A
search engine
*1
Instruction code
V/F
V/F
V/F
A0
0
A1
0
A2
0
A3
0
A4
0
A5
0
A9
0
AA
0
AB
0
AC
0
AD
0
AE
0
AF
0
B0
0
B1
0
B2
0
B3
0
B4
0
B6
0
B7
0
B8
0
B9
0
BA
0
BB
0
BC
0
C1
0
C2
0
C3
0
C4
0
C5
0
C7
0
C8
0
C9
0
CA
0
CB
0
CC
0
CD
0
CE
0
CF
0
D0
0
×
D1
0
×
D2
0
×
D3
0
×
D4
0
×
D5
0
×
D6
0
×
D9
0
×
DA
0
×
9.5 Parameters (functions) and instruction codes under different control methods
*2
Control method
Copy
Magnetic flux
Magnetic flux
Magnetic flux
PM
PM
PM
×
×
×
×
×
×
×
×
×
×
×
×
×
Parameter
1
All
*3
*3
Clear
*3
clear
2
3
4
5
6
7
8
9
10
×
×
×
×
×
×
×
×
669
9. APPENDIX