 Output signal list
• A function listed below can be set to each output terminal.
• Refer to the following table and set the parameters. (0 to 99, 200 to 299: Positive logic, 100 to 199, 300 to 399: Negative
logic)
Setting
Positive
Negative
logic
logic
0
100
1
101
2
102
3
103
4
104
5
105
7
107
8
108
10
110
11
111
12
112
13
113
14
114
15
115
16
116
17
18
19
25
125
26
126
35
135
39
139
40
140
41
141
42
142
Downloaded from
ManualsNet.com
Signal
Function
name
RUN
Inverter running
*1
SU
Up to frequency
Instantaneous power failure/
IPF
*2
undervoltage
OL
Overload warning
FU
Output frequency detection
Second output frequency
FU2
detection
For manufacturer setting. Do not set.
Electronic thermal O/L relay
THP
pre-alarm
PU
PU operation mode
RY
Inverter operation ready
Y12
Output current detection
Y13
Zero current detection
FDN
PID lower limit
FUP
PID upper limit
PID forward/reverse rotation
RL
output
MC1
Electronic bypass MC1
MC2
Electronic bypass MC2
MC3
Electronic bypass MC3
FAN
Fan fault output
FIN
Heat sink overheat pre-alarm
TU
Torque detection
Y39
Start time tuning completion
Y40
Trace status
FB
Speed detection
FB2
Second speed detection
search engine
Operation
Output during operation when the inverter
output frequency reaches Pr.13 Starting
frequency or higher.
Output when the output frequency reaches
the set frequency.
Output when an instantaneous power failure
or undervoltage protection operation occurs.
Output while the stall prevention function
works.
Output when the output frequency reaches
the frequency set in Pr.42 (Pr.43 during
reverse rotation) or higher.
Output when the output frequency reaches
the frequency set in Pr.50 or higher.
Output when the cumulative electronic
thermal O/L relay value reaches 85% of the
trip level. (The electronic thermal O/L relay
function (E.THT/E.THM) is activated when
the value reaches 100%.)
Output when PU operation mode is selected. Pr.79
Output when the reset process is completed
after powering ON the inverter or when the
inverter is ready to start operation with the
start signal ON or during operation.
Output when the output current is higher than
the Pr.150 setting for the time set in Pr.151 or
longer.
Output when the output current is lower than
the Pr.152 setting for the time set in Pr.153 or
longer.
Output when the input value is lower than the
lower limit set for the PID control operation.
Output when the input value is higher than
the upper limit set for the PID control
operation.
Output during forward rotation operation in
the PID control operation.
Used to work the electronic bypass function.
Output when a fan fault occurs.
Output when the heat sink temperature rises
to 85% of temperature at which the protective
function of the Heat sink overheat is
activated.
Output when the motor torque is higher than
the Pr.864 setting.
Output when tuning at start-up is completed. Pr.95, Pr.574
Output during trace operation.
Output when the actual motor rotations per
minute (estimate) reaches the setting of
Pr.42 (Pr.50).
5.8 (M) Item and output signal for monitoring
1
2
Refer
Related
to
parameter
3
page
335
4
Pr.41
337
466,
Pr.57
472
5
Pr.22, Pr.23,
Pr.66, Pr.148,
290
Pr.149, Pr.154
6
Pr.42, Pr.43
337
Pr.50
337
7
Pr.9
266
8
240
9
335
10
Pr.150, Pr.151
339
Pr.152, Pr.153
339
Pr.127 to Pr.134,
Pr.575 to Pr.577,
419
Pr.1346, Pr.1370
Pr.135 to Pr.139,
404
Pr.159
Pr.244
273
602
Pr.864
341
400
Pr.1020 to
486
Pr.1047
Pr.42, Pr.50
337
331
5. PARAMETERS