 Installing the heat sink outside the enclosure
When the heat sink is installed outside the enclosure, the amount of heat generated by the inverter unit is shown in the following
tables. (For the details on protruding the heat sink through a panel, refer to
Voltage
FR-F820-00105(2.2K)
FR-F820-00167(3.7K)
FR-F820-00250(5.5K)
FR-F820-00340(7.5K)
FR-F820-00490(11K)
FR-F820-00630(15K)
FR-F820-00770(18.5K)
200 V class
FR-F820-00930(22K)
FR-F820-01250(30K)
FR-F820-01540(37K)
FR-F820-01870(45K)
FR-F820-02330(55K)
FR-F820-03160(75K)
FR-F820-03800(90K)
FR-F820-04750(110K)
FR-F840-00023(0.75K)
FR-F840-00038(1.5K)
FR-F840-00052(2.2K)
FR-F840-00083(3.7K)
FR-F840-00126(5.5K)
FR-F840-00170(7.5K)
FR-F840-00250(11K)
FR-F840-00310(15K)
FR-F840-00380(18.5K)
FR-F840-00470(22K)
FR-F840-00620(30K)
FR-F840-00770(37K)
400 V class
FR-F840-00930(45K)
FR-F840-01160(55K)
FR-F840-01800(75K)
FR-F840-02160(90K)
FR-F840-02600(110K)
FR-F840-03250(132K)
FR-F840-03610(160K)
FR-F840-04320(185K)
FR-F840-04810(220K)
FR-F840-05470(250K)
FR-F840-06100(280K)
FR-F840-06830(315K)
NOTE
• The figures indicate the amount of heat generated when the output current is the rated current, power supply voltage is 220 V
(200 V class) or 440 V (400 V class), and the carrier frequency is 2 kHz.
2.3.3
Cooling system types for inverter enclosure
From the enclosure that contains the inverter, the heat of the inverter and other equipment (transformers, lamps, resistors, etc.)
and the incoming heat such as direct sunlight must be dissipated to keep the in-enclosure temperature lower than the
permissible temperatures of the in-enclosure equipment including the inverter.
The cooling systems are classified as follows in terms of the cooling calculation method.
• Cooling by natural heat dissipation from the enclosure surface (totally enclosed type)
• Cooling by heat sink (aluminum fin, etc.)
40
2. INSTALLATION AND WIRING
2.3 Installation of the inverter and enclosure design
Downloaded from
ManualsNet.com
Inverter model
Heat sink section (outside of enclosure)
104
161
263
265
375
405
555
690
700
1035
1170
1520
1960
2165
2860
20
36
42
77
120
180
260
260
315
395
510
655
780
970
1400
1780
2235
2540
2830
3250
3700
4090
4650
5280
search engine
page
Amount of heat generated (W)
SLD
LD
95
147
240
235
340
365
500
615
665
925
1040
1360
1740
1930
2530
18
32
39
71
109
170
235
245
290
360
465
575
720
880
1140
1470
1820
1960
2500
2660
3250
3570
4090
4620
43.)
Control section (inside of enclosure)
SLD
36
35
39
38
47
45
90
85
150
140
165
150
215
200
260
235
300
285
415
375
480
440
600
540
790
710
855
780
1100
1000
35
32
39
38
43
41
53
49
55
51
65
60
85
80
110
100
135
125
170
160
230
210
275
250
330
300
370
340
600
500
740
630
915
755
1060
840
1220
1100
1400
1140
1600
1400
1760
1530
2000
1760
2270
1980
LD