*2
The Inverter run enable signal is in the initial status for the separated converter type.
*3
JOG operation/automatic restart after instantaneous power failure/start self-holding selection/reset cannot be controlled over a network, so in the
initial status bit 8 to bit 11 are invalid. To use bit 8 to bit 11, change the signal by Pr.185, Pr.186, Pr.188, or Pr.189 (Input terminal function
selection)
*4
During RS-485 communication through the PU connector, only the Forward rotation command and Reverse rotation command signals can be
used.
 Inverter status monitor
Instruction
Item
Inverter
status
H7A
monitor
Inverter
status
H79
monitor
(extended)
*1
The signal within parentheses ( ) is the initial status. The description changes depending on the setting of Pr.190 to Pr.196 (Output terminal
function selection).
*2
No function is assigned in the initial status for the separated converter type.
 Multi command (HF0)
• Sending data format from computer to inverter
Format
1
A2
ENQ
• Reply data format from inverter to computer (No data error detected)
Format
1
C1
STX
*1
Specify the data type of sending data (from computer to inverter).
*2
Specify the data type of reply data (from inverter to computer).
*3
Combination of data 1 and data 2 for sending
Data type
0
1
Downloaded from
ManualsNet.com
(page
373) (A reset can be executed by the instruction code HFD.)
Bit
code
length
b0: RUN (Inverter running)
b1: Forward rotation output
b2: Reverse rotation output
b3: SU (Up to frequency)
b4: OL (Overload warning)
8 bits
b5: IPF (Instantaneous power
failure/undervoltage)
b6: FU (Output frequency
detection)
b7: ABC1 (Fault)
b0: RUN (Inverter running)
b1: Forward rotation output
b2: Reverse rotation output
b3: SU (Up to frequency)
b4: OL (Overload warning)
b5: IPF (Instantaneous power
failure/undervoltage)
16 bits
b6: FU (Output frequency
detection)
b7: ABC1 (Fault)
b8: ABC2 (–)
b9: Safety monitor output
b10 to b14: –
b15: Fault occurrence
2
3
4
5
6
Inverter
Instruction
Time
station No.
code (HF0)
delay
2
3
4
5
Send
Receive
Inverter
data
data
station No.
*1
*2
type
type
Data 1
Operation command
Set frequency (RAM)
(extended)
Operation command
Set frequency (RAM,
(extended)
EEPROM)
search engine
*1
Description
*2
[Example 1] H0003
b15
*2
0
[Example 2] H8080
b15
1
Number of characters
7
8
9
10
Send
Receive
data
data
*3
Data 1
*1
*2
type
type
Number of characters
6
7
8
9
10
Error
Error
code
code
*4
Data 1
*5
*5
1
2
Data 2
Run command (extended) is same as instruction code HF9. (Refer
to
page
518.)
Example
[Example 1] H03
During forward
rotation
b7
0
0
0
0
0
0
[Example 2] H80
Stop at fault
occurrence
b7
1
0
0
0
0
0
During forward rotation
0
0
0
0
0
0
0
0
0
Stop at fault occurrence
0
0
0
0
0
0
0
1
0
11
12
13
14
15
*3
Data 2
11
12
13
14
15
*4
Data 2
Remarks
5.12 (N) Communication operation parameters
1
2
3
b0
4
1
1
b0
5
0
0
6
b0
7
0
0
0
0
1
1
b0
8
0
0
0
0
0
0
9
10
16
17
18
19
CR/
Sum check
LF
16
17
18
19
CR/
ETX
Sum check
LF
519
5. PARAMETERS