 PM motor test operation (Pr.800 = "9")
• A test operation for speed control is available without connecting a motor to the inverter.
The speed calculation changes to track the speed command, and such speed changes can be checked on the operation
panel or by outputting it as analog signals to terminal FM/CA or AM.
NOTE
• Since current is not detected and voltage is not output, monitors related to current and voltage such as output current and
output voltage, etc. and output signals do not function.
 I/O signal status during the test operation
• During the test operation, the following signals are disabled.
 Input terminal function selection (Pr.178 to Pr.189)
• V/F switchover (X18) signal
• Start-time tuning start external input (X28) signal
 Output terminal function selection (Pr.190 to Pr.196)
• Electronic thermal O/L relay pre-alarm (THP) signal
• Start time tuning completion (Y39) signal
Parameters referred to
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
 Status of the monitoring during the test operation
○: Enabled
×: Disabled (0 is displayed at any time.)
Δ: A cumulative total before the test operation is displayed.
—: Not available
Monitor item
Output frequency
Fault indication
Frequency setting value
Motor speed
Converter output voltage
Electronic thermal O/L relay load factor ×
Output current peak value
Converter output voltage peak value
Load meter
Cumulative energization time
Reference voltage output
Actual operation time
Cumulative energy
Trace status
Station number (RS-485 terminals)
Station number (PU connector)
Station number (CC-Link)
Energy saving effect
Cumulative energy saving
PID set point
PID measured value
*1
The monitoring-enabled items differ depending on the output interface (operation panel, parameter unit, terminal FM/CA, or terminal AM). For the
details, refer to
*2
When the inverter operation is switched to the test operation, the indication is changed to 0. When PM motor control is selected again after the
test operation, the output current peak value and the electronic thermal relay load factor from the last operation are displayed.
*3
The output is enabled via terminal AM only.
178
5. PARAMETERS
5.2 Control method
Downloaded from
ManualsNet.com
selection)page 373
selection)page 330
Output via
Monitoring
on DU/PU
FM/CA/AM
*2
×
*2
×
×
Δ
×
Δ
page
314.
search engine
terminal
Monitor item
PID deviation
Input terminal status
Output terminal status
Option input terminal status
Option output terminal status
*2
Motor thermal load factor
*2
Inverter thermal load factor
PTC thermistor value
PID measured value 2
PID input pressure value
Remote output 1
Remote output 2
Remote output 3
Remote output 4
PID manipulated variable
Second PID set point
Second PID measured value
Second PID deviation
Second PID measured value 2
Second PID manipulated variable
Output via
Monitoring
terminal
on DU/PU
FM/CA/AM
*3
*4
*4
*4
*4
*3
*3
*3