Mitsubishi Electric FR-F800 Series Instruction Manual page 334

Hide thumbs Also See for FR-F800 Series:

Advertisement

Setting
Positive
Negative
logic
logic
86
186
87
187
88
188
89
189
90
190
91
191
92
192
93
193
94
194
95
195
96
196
98
198
99
199
200
300
201
301
202
302
203
303
204
304
205
305
206
306
207
307
208
308
Downloaded from
ManualsNet.com
Signal
Function
name
Control circuit capacitor life
Y86
(for Pr.313 to Pr.322)
Main circuit capacitor life
Y87
(for Pr.313 to Pr.322)
Cooling fan life
Y88
(for Pr.313 to Pr.322)
Inrush current limit circuit life
Y89
(for Pr.313 to Pr.322)
Y90
Life alarm
Fault output 3 (Power-OFF
Y91
signal)
Energy saving average value
Y92
updated timing
Y93
Current average monitor
ALM2
Fault output 2
Y95
Maintenance timer
REM
Remote output
LF
Alarm
ALM
Fault
FDN2
Second PID lower limit
FUP2
Second PID upper limit
Second PID forward/reverse
RL2
rotation output
During second PID control
PID2
activated
During second PID output
SLEEP2
shutoff
Y205
Second PID deviation limit
Cooling fan operation
Y206
command
Y207
Control circuit temperature
PS
PU stopped
search engine
Operation
Output when the control circuit capacitor
*5
approaches the end of its life.
Output when the main circuit capacitor
*2*5
approaches the end of its life.
Output when the cooling fan approaches the
*5
end of its life.
Output when the inrush current limit circuit
*2*5
approaches the end of its life.
Output when any of the control circuit
capacitor, main circuit capacitor, inrush
current limit circuit, or the cooling fan
approaches the end of its life.
Output when the Fault occurs due to an
inverter circuit fault or connection fault.
Switches between ON and OFF every time
the average energy saving is updated during
the energy saving monitoring. This signal
cannot be assigned to any of the relay output
terminal (Pr.195, Pr.196, Pr.320 to Pr.322).
Output in pulses for transmission of the
average current value and the maintenance
timer value. This signal cannot be assigned to
any of the relay output terminal (Pr.195,
Pr.196, Pr.320 to Pr.322).
Output when the inverter's protective function
is activated to stop the power output (when
the Fault occurs).
The signal output continues during the
inverter reset and stops after the inverter
*6
reset finishes.
Output when the value of Pr.503 reaches the
Pr.504 setting or higher.
Output via a terminal by setting a proper
number in a relative parameter.
Output when an Alarm fault (fan fault or a
communication error) occurs.
Output when the inverter's protective function
is activated to stop the power output (when
the Fault occurs). The signal output stops
when the inverter reset starts.
Output when the input value is lower than the
lower limit set for the second PID control
operation.
Output when the input value is higher than
the upper limit set for the second PID control
operation.
Output during forward rotation operation in
the second PID control operation.
Output during the second PID control
operation.
Output while the second PID output
suspension function is activated.
Output when the absolute deviation value
exceeds the limit value during the second PID
control operation.
Output when the cooling fan operation is
commanded.
Output when the temperature of the control
circuit board reaches the detection level or
higher.
Output while the PU is stopped.
Related
parameter
Pr.255 to Pr.259
Pr.52, Pr.54,
Pr.158, Pr.891 to
Pr.899
Pr.555 to Pr.557
Pr.503, Pr.504
Pr.495 to Pr.497
Pr.121, Pr.244
Pr.753 to Pr.758
Pr.753 to Pr.758,
Pr.1147 to
Pr.1149
Pr.753 to Pr.758,
Pr.1145, Pr.1146
Pr.244
Pr.663
Pr.75
5. PARAMETERS
5.8 (M) Item and output signal for monitoring
Refer
to
1
page
2
3
220
4
336
5
324
6
7
225
8
336
9
224
341
10
273,
500
336
419
273
347
196
333