Download Print this page

(C) Motor Constant Parameters - Mitsubishi Electric FR-F800 Series Instruction Manual

Hide thumbs Also See for FR-F800 Series:

Advertisement

5.10
To select the motor to be used
To maximize the performance of the
induction motor
To maximize the performance of the
PM motor
To perform high accuracy operation
without being affected by temperature
and high-torque/ultra-low speed
5.10.1 Applied motor
By setting the applied motor type, the thermal characteristic appropriate for the motor can be selected.
When using a constant-torque or PM motor, the electronic thermal O/L relay function is set according to the motor.
When the Advanced magnetic flux vector control or PM motor control is selected, the motor constant necessary for control (SF-
PR, SF-JR, SF-HR, SF-JRCA, SF-HRCA, MM-EFS, MM-THE4, etc.) is also selected at the same time.
Pr.
71
Applied motor
C100
450
Second applied motor
C200
Downloaded from
ManualsNet.com

(C) Motor constant parameters

Purpose
Applied motor
Offline auto tuning
PM motor offline auto
tuning
Online auto tuning
Name
Initial value
0
9999
search engine
Parameter to set
P.C100, P.C200
P.C000, P.C100 to
P.C105, P.C107,
P.C108, P.C110,
P.C120 to P.C126,
P.C200 to P.C205,
P.C207, P.C208,
P.C210, P.C220 to
P.C226
P.C000, P.C100 to
P.C108, P.C110,
P.C120, P.C122,
P.C123, P.C126,
P.C130 to P.C133,
P.C135, P.C150,
P.C182, P.C185,
P.C200 to P.C208,
P.C210, P.C220,
P.C222, P.C223,
P.C226, P.C230 to
P.C233, P.C235,
P.C282, P.C285
P.C111, P.C211
Setting range
0 to 6, 13 to 16, 20, 23, 24, 40,
43, 44, 50, 53, 54, 70, 73, 74,
210, 213, 214, 240, 243, 244,
8090, 8093, 8094, 9090, 9093,
9094
0, 1, 3 to 6, 13 to 16, 20, 23, 24,
40, 43, 44, 50, 53, 54, 70, 73, 74,
210, 213, 214, 240, 243, 244,
8090, 8093, 8094, 9090, 9093,
9094
9999
Refer to page
Pr.71, Pr.450
379
Pr.9, Pr.51, Pr.71,
Pr.80 to Pr.84, Pr.90 to
Pr.94, Pr.96, Pr.450,
Pr.453 to Pr.463,
383
Pr.684, Pr.707, Pr.724,
Pr.744, Pr.745, Pr.859,
Pr.860
Pr.9, Pr.51, Pr.71,
Pr.80, Pr.81, Pr.83,
Pr.84, Pr.90, Pr.92,
Pr.93, Pr.96, Pr.450,
Pr.453, Pr.454, Pr.456
to Pr.458, Pr.460,
Pr.461, Pr.463, Pr.684,
392
Pr.702, Pr.706, Pr.707,
Pr.711, Pr.712, Pr.717,
Pr.721, Pr.724, Pr.725,
Pr.738 to Pr.747,
Pr.788, Pr.859, Pr.860,
Pr.1002, Pr.1412,
Pr.1413
Pr.95, Pr.574
400
Description
By selecting a motor, the thermal characteristic
and motor constant of each motor are set.
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
5. PARAMETERS
5.10 (C) Motor constant parameters
1
2
3
4
5
6
7
8
9
10
379