NOTE
• "
device and try the operation again.
• "
lower or FR-F840-01160(55K) or lower inverters and the FR-F820-03160(75K) or higher or FR-F840-01800(75K) or higher
inverters. When CP and 0.00 are displayed alternately, set Pr.989 Parameter copy alarm release as shown below (initial
value).
After setting Pr.989, perform setting of Pr.9, Pr.30, Pr.51, Pr.56, Pr.57, Pr.61, Pr.70, Pr.72, Pr.80, Pr.82, Pr.90 to Pr.94,
Pr.453, Pr.455, Pr.458 to Pr.462, Pr.557, Pr.859, Pr.860, and Pr.893 again.
• When the copy destination is other than the FR-F800 series or when parameter copy is attempted after the parameter copy
reading was stopped, the model error "
• Refer to the parameter list on
• When the power is turned OFF or an operation panel is disconnected, etc. during parameter copy writing, write again or check
the setting values by parameter verification.
• When parameters are copied from a different-capacity inverter, there are parameters with different initial values depending on
the inverter capacity, so the setting values of some parameters will be automatically changed. After performing a parameter
copy from a different-capacity inverter, check all the parameter settings. (Refer to the parameter list
parameters with different initial values depending on individual inverter capacity.)
584
5. PARAMETERS
5.16 Copying and verifying parameters using a USB memory
Downloaded from
ManualsNet.com
" or "
" appears when a USB memory device error occurred. Check the connection of the USB memory
" and "
" are displayed alternately when parameter copy is performed between the FR-F820-02330(55K) or
Pr.989 setting
10
Cancels the warning of FR-F820-02330(55K) or lower and FR-F840-01160(55K) or lower.
100
Cancels the warning of FR-F820-03160(75K) or higher and FR-F840-01800(75K) or higher.
page 668
search engine
" appears.
for the availability of parameter copy.
Operation
(page
140) for details of