NOTE
• The Y39 signal remains ON after the motor is stopped as long as the second flux remains.
• The X28 signal is disabled while the Y39 signal is ON.
• The STF and STR signals are enabled after completing tuning at start.
• The Inverter running (RUN) signal is not turned ON during online auto tuning. The RUN signal is turned ON after starting up.
• The setting is invalid under V/F control or PM motor control.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) or Pr.190 to Pr.196 (Output
terminal function selection) may affect the other functions. Set parameters after confirming the function of each terminal.
 Tuning the second motor (Pr.574)
• When one inverter switches the operation between two different motors, set the second motor in Pr.450 Second applied
motor. (In the initial setting, no second motor is applied. (Refer to
• Perform tuning using Pr.574 Second motor online auto tuning.
• Pr.574 is enabled when the Second function selection (RT) signal is turned ON.
Pr.
450
453
454
*1
If a motor with substantially low rated current compared with the inverter rated current is used, speed and torque accuracies may deteriorate due
to torque ripples, etc. Set the rated motor current to about 40% or higher of the inverter rated current.
NOTE
• The RT signal is the Second function selection signal. The RT signal also enables other second functions. (Refer to
The RT signal is assigned to terminal RT in the initial status. Set "3" in one of Pr.178 to Pr.189 (Input terminal function
selection) to assign the RT signal to another terminal.
• Changing the terminal assignment using Pr.178 to Pr.189 (input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.9 Electronic thermal O/L
Pr.71 Applied
motorpage 379
Pr.80 Motor
capacitypage
Pr.81 Number of motor
Pr.96 Auto tuning
setting/statuspage
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
402
5. PARAMETERS
5.10 (C) Motor constant parameters
Downloaded from
ManualsNet.com
Applied motor
Motor capacity (with the rated motor current equal to or less than the inverter rated current)
Number of motor poles
relaypage 266
177,
page
383,
page 392
polespage
177,
page
383,
page 392
383,
page 392
selection)page 373
selection)page 330
search engine
page
379.))
Description
*1
page
373.)

Advertisement

loading