A) Application Parameters - Mitsubishi Electric FR-F800 Series Instruction Manual

Hide thumbs Also See for FR-F800 Series:

Advertisement

5.11
To operate by switching between the
inverter and the commercial power
supply operation
To reduce the standby power
To count the number of inverter starting
times
To strengthen or weaken the frequency
at a constant cycle
To remove stains on the impellers or
fans of pumps by repeating a forward/
reverse rotation
To perform process control, such as for
the pump flow volume and air volume
To set the constant optimal for PID
control
To continue operating at analog current
input loss
To restart without stopping the motor at
instantaneous power failure
To decelerate the motor to a stop at
power failure
To operate with sequence program
To store the inverter running status to a
USB memory device
Downloaded from
ManualsNet.com

(A) Application parameters

Purpose
Electronic bypass function
Self power management
Start count monitor
Traverse operation
Cleaning function
Multi-pump function
(Advanced PID function)
PID Pre-charge function
PID display adjustment
PID control
PID control enhanced
functions
PID gain tuning
4 mA input check
Automatic restart after
instantaneous power failure
/ flying start function for
induction motors
Frequency search accuracy
improvement (V/F control,
offline auto tuning)
Automatic restart after
instantaneous power failure
/ flying start function for
IPM motors
Power failure time
deceleration-to-stop
function
PLC function
Trace function
search engine
Parameter to set
P.A000 to P.A005
Pr.135 to Pr.139, Pr.159
P.A002, P.A006,
Pr.30, Pr.137, Pr.248,
P.A007, P.E300
Pr.254
P.A170, P.A171
Pr.1410, Pr.1411
P.A300 to P.A305
Pr.592 to Pr.597
P.A420 to P.A430
Pr.1469 to Pr.1479
P.A400 to P.A414,
Pr.578 to Pr.591, Pr.1370,
P.A442
Pr.1376
P.A616 to P.A620,
Pr.760 to Pr.769, Pr.1132,
P.A626, P.A656 to
Pr.1133
P.A660, P.A666
P.A600, P.A630 to
Pr.759, C42 to C45
P.A633, P.A670 to
(Pr.934, Pr.935), Pr.1136
P.A673
to Pr.1139
Pr.127 to Pr.134, Pr.553,
P.A442, P.A457,
Pr.554, Pr.575 to Pr.577,
P.A601 to P.A607,
Pr.609, Pr.610, Pr.753 to
P.A610 to P.A615,
Pr.758, Pr.1015, Pr.1134,
P.A621 to P.A625,
Pr.1135, Pr.1140,
P.A640 to P.A644,
Pr.1141, Pr.1143 to
P.A650 to P.A655,
Pr.1149, Pr.1346,
P.A661 to P.A665,
Pr.1370, Pr.1460 to
P.A683 to P.A689
Pr.1466
P.A440 to P.A457,
Pr.111, Pr.1346, Pr.1361
P.A627 to P.A629,
to Pr.1375, Pr.1377 to
P.F031
Pr.1381
P.A690 to P.A698
Pr.1211 to Pr.1219
P.A680 to P.A682
Pr.573, Pr.777, Pr.778
P.A700 to P.A705,
Pr.57, Pr.58, Pr.162 to
P.A710 to P.F003
Pr.165, Pr.299, Pr.611
P.A700, P.A711,
Pr.96, Pr.162, Pr.298,
P.A712, P.C110,
Pr.463, Pr.560
P.C210
P.A700, P.A702,
Pr.57, Pr.162, Pr.611
P.F003
P.A730 to P.A735,
Pr.261 to Pr.266, Pr.294
P.A785
Pr.414 to Pr.417, Pr.498,
P.A800 to P.A805,
Pr.675, Pr.1150 to
P.A811 to P.A859
Pr.1199
P.A900 to P.A906,
P.A910 to P.A920,
Pr.1020 to Pr.1047
P.A930 to P.A939
5.11 (A) Application parameters
1
2
Refer to
page
404
3
410
4
413
414
5
415
450
6
445
7
442
8
419
9
10
459
437
369
466
474
472
478
483
486
403
5. PARAMETERS