• When copying the traced data to a USB memory device, the operating status of the USB host can be checked with the
inverter LED.
Refer to
page 78
LED display status
OFF
ON
Blinking rapidly
Blinking slowly
• During trace operation, the Trace status (Y40) signal can be output.
To use the Y40 signal, set "40 (positive logic) or 140 (negative logic)" in one of Pr.190 to Pr.196 (Output terminal function
selection) to assign function to an output terminal.
NOTE
• Changing the terminal assignment using Pr.190 to Pr.196 (Output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.52 Operation panel main monitor
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.196 (Output terminal function
494
5. PARAMETERS
5.11 (A) Application parameters
Downloaded from
ManualsNet.com
for an outline of the USB communication function.
No USB connection.
The communication is established between the inverter and the USB device.
Traced data is being transmitted. (In the memory mode, transmission command is being issued. In the recorder mode,
sampling is being performed.)
Error in the USB connection.
selectionpage 305
selection)page 373