 PID monitor indicator setting (Pr.999 = "1 or 2")
Pr.
759
PID unit selection
1142
Second PID unit selection
774
Operation panel monitor selection 1
775
Operation panel monitor selection 2
776
Operation panel monitor selection 3
C42 (934)
PID display bias coefficient
C44 (935)
PID display gain coefficient
1136
Second PID display bias coefficient
1138
Second PID display gain coefficient
3-line monitor setting
Direct setting
Dedicated parameter list function
*1
Enabled when the FR-LU08 (-01) is used.
*2
Enabled when the FR-PU07 is used.
*3
Enabled when the FR-PU07-01 is used.
 3-line monitor setting
On the operation panel or parameter unit, the 3-line monitor is used as the first monitor.
 Direct setting
Pressing the [FUNC] key on the FR-PU07-01 displays the direct setting screen. The PID action set point can be directly set
regardless of the operation mode or Pr.77 Parameter write selection setting.
Pressing the [FUNC] key on the direct setting screen displays the function menu.
Direct setting
Direct setting 1
Direct setting 2
 Dedicated parameter list function
Pressing the [PrSET] key of the FR-PU07-01 displays the dedicated parameter list. Parameters that need to be set first for the
PID extended display setting are listed.
Dedicated parameter list
No.1
No.2
No.3
NOTE
• The display of parameters other than the above may be changed due to changes in C42 or C44. Set the PID monitor indicator
before changing the settings of other parameters.
• To use the direct setting on the LCD operation panel, set Pr.1000 Direct setting selection. (Refer to
 GOT initial setting (PU connector) (Pr.999 = "10, 12")
Pr.
79
Operation mode selection
118
PU communication speed
119
PU communication stop bit length / data length 1
120
PU communication parity check
121
PU communication retry count
122
PU communication check time interval
123
PU communication waiting time setting
124
PU communication CR/LF selection
340
Communication startup mode selection
414
PLC function operation selection
*1
The setting is changed when Pr.414 = "0" (initial setting).
212
5. PARAMETERS
5.4 (E) Environment setting parameters
Downloaded from
ManualsNet.com
Name
Parameter to be set
Pr.133 PID action set point
Pr.755 Second PID action set point
Parameter to be set
Pr.999 Automatic parameter setting
Pr.934 PID display bias coefficient
Pr.935 PID display bias analog value
Name
search engine
Initial value
Pr.999 = "1"
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
Invalid
Invalid
Invalid
Initial value
Pr.999 = "10"
0
1
192
192
10
2
1
1
9999
9999
9999
9999
0 ms
1
1
0
0
0
Pr.999 = "2"
Refer to page
4
442
4
52
53
305
54
0
100
442
0
100
*1*2*3
Enabled
*3
Enabled
*3
Enabled
page
201.)
Pr.999 = "12"
Refer to page
1
240
1152
0
1
9999
505
9999
0 ms
1
0
250
*1
483
2