 Details of the supported properties
• The details of the properties supported by the network port are as follows.
Property
Max Info Frames
Max Master
Object Identifier
Object Name
Object Type
Out Of Service
Status Flags
Property List
Reliability
Network Type
Protocol Level
Network Number
Network Number Quality
Changes Pending
APDU Length
Link Speed
MAC Address
IP Address
IP Subnet Mask
IP Default Gateway
IP DNS Server
 Supported BACnet object
• ANALOG INPUT
Object Identifier
0
1
2
*1
R: Read only, W: Read/Write (Commandable values not supported), C: Read/Write (Commandable values supported)
Downloaded from
ManualsNet.com
Shows the maximum number of frames that the inverter can transmit while it owns the token. When
a value is written, it is reflected to the Pr.727 setting.
Shows the maximum address for master node. When a value is written, it is reflected to the Pr.726
setting.
Shows the unique numeric code to identify the object.
Shows the object name.
Network Port: NETWORK_PORT (56)
FALSE (0)
Always 0.
Shows the property identifier list.
Shows the reliability of the network port.
Fixed to no-fault-detected (0) for the FR-F800.
Shows the communication method of the network.
Fixed to MSTP (2) for the FR-F800.
Shows the protocol level.
Fixed to BACNET_APPLICATION (2) for the FR-F800.
Shows the network number.
Fixed to 0 for the FR-F800. If a value other than "0" is written, an error code
VALUE_OUT_OF_RANGE (37) will be returned.
Shows the quality of the network port number.
Fixed to UNKNOWN (0) for the FR-F800.
If the property value whose change is to be reflected at a reset is changed, TRUE is returned.
FALSE is returned after the status is initialized by a reset.
Shows the maximum number of octets.
Fixed to 50 octets for the FR-F800.
Shows the communication speed in the unit of bit/s.
The Pr.332 setting value × 100 equals the communication speed.
Shows the MAC address of the network port.
The Pr.331 setting value is used for the MAC address.
For example, the MAC address is 7F when Pr.331 = "127".
A rejection code (0) is displayed when the property is read.
A rejection code (0) is displayed when the property is read.
A rejection code (0) is displayed when the property is read.
A rejection code (0) is displayed when the property is read.
Present Value
Object Name
Access Type
Terminal 1
R
Terminal 2
R
Terminal 4
R
search engine
Details
Description
*1
Represents actual input voltage of terminal 1.
(The range varies depending on the Pr.73 and Pr.267
settings.
-10 to +10 V (-100% to +100%),
-5 to +5 V (-100% to +100%))
Represents actual input voltage (or input current) of
terminal 2.
(The range varies depending on the Pr.73 and Pr.267
settings.
0 to 10 V (0% to 100%),
0 to 5 V (0% to 100%),
0 to 20 mA (0% to 100%))
Represents actual input current (or input voltage) of
terminal 4.
(The range varies depending on the Pr.73 and Pr.267
settings.
2 to 10 V (0% to 100%),
1 to 5 V (0% to 100%),
4 to 20 mA (0% to 100%))
5.12 (N) Communication operation parameters
1
2
3
4
5
6
7
8
9
10
Unit
percent
(98)
percent
(98)
percent
(98)
537