Jogging - Siemens Sinamics G110M Operating Instructions Manual

Sinamics series distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Advanced commissioning

6.6 Jogging

6.6
Jogging
The "Jog" function is typically used to temporarily move a machine part using local control
commands, e.g. a transport conveyor belt.
Figure 6-14
After switching on, the motor accelerates to the setpoint, jog 1 or setpoint, jog 2. The two
different setpoints can, for example, be assigned to motor clockwise and counter-clockwise
rotation.
When jogging, the same ramp-function generator is active as for the ON/OFF1 command.
176
Commands "Jog 1" or "Jog: 2" switch the motor on and off.
The commands are only active when the inverter is in the "Ready for
switching on" state.
Behavior of the motor when "jogging"
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 09/2017, FW V4.7.9, A5E31298649B AH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents