Add Packet Bus Support

Add Packet Bus Support
Disable Alarm Origination
1. Type change system-parameters maintenance and press
2. Set the Alarm Origination Activated field to n.
!
3. For some DEFINITY ECS software versions, disable Cleared Alarm
Notification and Restart Notification before submitting the
form.
Save Translations
1. Type save translation and press
translation information in memory and write it to the translation card.
Install Circuit Packs
1. Install the appropriate circuit packs. See
Table 5-6. Circuit Pack Locations for Packet Bus in PPN
Circuit Pack
TN799C
Administer the Bus Bridge
1. Type change system-parameters maintenance and press
2. On Page 2, Type y in the PKTINT 2 field.
3. Choose the port bandwidths or use the default and submit the form.
4. Verify the bus bridge LED is lit on the TN799C C-LAN circuit pack. This
indicates that the packet bus is enabled.
555-233-118
CAUTION:
If you do not disable Alarm Origination, the system may generate
alarms, resulting in unnecessary trouble tickets.
Carrier
Any
. This instructs the system to take all
Enter
Table
5-6.
Quantity
1
Any Available Port Slot
Issue 5 October 2002
.
Enter
Slot
.
Enter
5-43