Install and Wire Telephones and Other Equipment
The general steps to connect a telephone are:
1. Choose a device to connect such as a 302C1 Attendant Console.
2. Choose the port circuit pack and its carrier and slot number, such as
TN754B, Cabinet 1, Carrier A, Slot 06.
3. Choose a port circuit on the port circuit pack, such as Port 05.
Figure Notes
1. 302C1 attendant console
2. 4-wire digital line circuit pack
Figure 1-30. 302C1 to Digital Line Circuit Pack Wiring
4. Install cross-connect jumpers to wire the terminal to the port circuit pack.
See
555-233-118
TXT
1
TXR
2
PXT
3
PXR
6
7
8
Figure
1-30. This pinout is for a 4-wire Digital Line circuit pack.
TXT5
39
14
TXR5
40
PXT5
15
PXR5
302cwire RPY 012098
3. -48 VDC from adjunct power
4. Ground from adjunct power
Issue 5 October 2002
1-67