Avaya CMC1 Installation, Upgrades And Additions page 242

Table of Contents

Advertisement

Adding or Removing Hardware
6. The Node Name field is the same as the one previously administered. (See
change node-names
7. Set the Subnet Mask field according to your network requirements.
8. The Gateway Address is usually the same as the TN2501AP circuit
pack's IP address, usually with the fourth octet changed. Be sure to set this
address according to your network requirements.
9. Leave the Net Rgn (Network Region) field at its default value. This field is
not used for VAL.
10. Press
add data-module
Use this command to administer the data module that is associated with the
TN2501AP ethernet port.
1. At the SAT, type add data-module extension/next and press
The Data Module screen appears.
add data-module 30006
Data Extension: 30006
Type: ethernet
Port: 1b0333
Link: 5
Network uses 1's for Broadcast Addresses? y
Screen 5-16. Data Module screen (add data-module extension)
2. Set the Type field to ethernet.
3. Set the Port field to correspond to the circuit pack location.
In the example above, 1b0333 means Cabinet 1, Carrier B, Slot 3, Port 33.
5-40
Issue 5 October 2002
ip)
NOTE:
If you press
, a list of administered node names appears
Help
(including the name you administered with the change node-names
ip command), and you can select from the list.
to save the changes.
ENTER
DATA MODULE
Name: VAL#2 Data Module
NOTE:
The port number (final two digits) is always 33 for the TN2501AP
circuit pack.
RETURN
Page
1 of
1
SPE A
555-233-118
.