Avaya CMC1 Installation, Upgrades And Additions page 275

Table of Contents

Advertisement

Add IP Solutions
6. If not, type MEDPRO in the slot just above TN802B slot and press
Changing the one entry automatically changes the entry above it. If it is in
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press
8. Type in the information for the TN802B IP Interface,
9. Set the Enabled field to y, and press
At this time the TN802B LCD reads PC BOOT *, and about 3 to 4 minutes
later reads MEDPRO * with the asterisk flashing
.
change ip-interfaces
Network regions are interconnected?
En-
abled Type
Addr Rgn
n
C-LAN 01A09 TN799
y
MEDPRO 01A13 TN802 B med-a1
n
n
n
n
n
n
n
n
n
n
n
n
n
Test the External Connection to the LAN
To test the external IP connections, ping the IP Interface server, and ping a known
computer connected to your network. If everything is configured correctly, the
Result column on the Ping Results screen reads pass. If it reads abort, verify
the IP-address information and check the connectivity, including the cabling.
1. Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press
The variable nnn.nnn.nnn.nnn is the IP address of the TN802B IP
Interface and UUCSS is the cabinet, carrier, and slot of the TN802B IP
Interface.
555-233-118
NOTE:
The customer provides the IP address, subnet mask, and gateway
address.
Slot
Code Sfx Node Name
clan-a1
.
Enter
.
Enter
Page
n
Subnet Mask
255.255.255.0
192.168.1 .100 1
255.255.255.0
192.168.1 .21 1
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
Issue 5 October 2002
.
Enter