Avaya CMC1 Installation, Upgrades And Additions page 114

Table of Contents

Advertisement

Installing and Cabling the Cabinets
.
Table 1-20. Trunk/Test Switches
Switch
Number
1
2
3
4
5
6
7
8
9
10
11
12
4. Connect a 25-pair cable between the male RJ21 25-pair connector on the
808A and the yellow field on the MDF.
pinouts.
5. Make cross-connections for each emergency trunk/emergency station pair.
See
6. On the trunk identification label at the bottom of the panel, record the trunk
line, extension, and location for each circuit.
7. To each voice terminal designated as an emergency terminal, attach a
label identifying it as such. The labels are provided with the unit.
8. Check the system for normal operation as follows:
a. Place the test switch (switch 12) in NORMAL OPERATION.
b. Ensure the power supply is providing -48 VDC at 80 mA maximum.
c. Check wiring connections.
d. Verify there is dial tone on all emergency transfer sets.
1-100
Issue 5 October 2002
Circuit
Number
1
1
2
2
3
3
4
4
5
5
Not Used
Test Switch
Figure 1-47 on page 1-103
The power LED should be ON.
Table 1-21 on page 1-101
and
Figure 1-48 on page
shows the
1-104.
555-233-118