Install Emergency Transfer Unit and Associated
Telephones
4. Connect the ST leads on the yellow emergency transfer row/connecting
block for each emergency transfer telephone to the ST terminal
appearance in the yellow trunk/auxiliary field. The ST terminal leads should
be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first
pair of any 3-pair group).
5. Connect the ST leads from the terminal in Step 4 to the assigned terminal
in the blue or white station distribution field.
Trunk/Auxiliary Field: Telephone Used for Emergency Transfer and as
Normal Extension
1. Connect a pair of wires between the -48V and GRD terminals on the yellow
emergency transfer row/connecting block to the EM TRANS RELAY PWR
terminal. See
2. Connect CO trunk leads from the purple field to the TC terminals on the
yellow emergency transfer row/connecting block for each trunk.
3. Connect CO trunk leads from the green field to the TK terminals on the
yellow emergency transfer row/connecting block for each trunk.
4. Connect telephone leads from the purple analog line board row/ connecting
block to the LC terminals on the yellow emergency transfer row/connecting
block for each telephone.
5. Connect ST leads on the yellow emergency transfer row/connecting block
for each emergency transfer telephone to the ST terminal appearance in
the purple trunk/auxiliary field.
6. Connect the ST leads from the terminal in Step 5 to the assigned terminal
in the blue or white station distribution field.
Telephone Installation
1. Connect the telephone to the information outlet.
2. Install patch cords/jumper wires between the system side and the station
side of the station distribution field on the MDF.
555-233-118
Figure 1-48 on page
1-104.