Installing and Cabling the Cabinets
5. Set the Modem Connection: field to external if a modem is installed.
Set the field to none if no modem is installed. This field must be
administered or alarms will be generated.
6. Set the Data Bits: field to 8 (default).
7. Set the Parity: field to none (default).
8. For non-United States installations, set the remaining modem fields as
shown in
9. Press
Table 1-24. Modem Fields
Field
Description
Default is none. Set to external if a modem is used.
Modem
Connection
This field is 20 characters long and permits alphanumeric characters to
Modem Name
provide a unique qualifier for a given modem.
Informs modem that communication with the data source UART is
RTS/CTS
driven with RTS/CTS flow control. The default 6-character field name is
Enabled
&H1. Set the field name to \Q3 for Intel modems. This field is not
case-sensitive.
Configures modem as an asynchronous device. This 8-character field
Asynchronous
name has a default value of &M0 (default). Set the field to &M0&Q0 for
Data Mode
Intel modems. This field is not case-sensitive.
Adjusts the speed of the data source (DTE) UART to the outgoing
DTE
(modem-to-modem) data rate. At maximum, this speed is 9600 baud. It
Auto-Data
is not desirable to have the serial data fill the modem buffer faster than
Speed
the outgoing data rate, since data compression is disabled. The field
name has a 6-character blank default value. The Paradyne products
use S90=1 to enable this functionality while the Intel product uses \J1
to enable similar functionality. This field is not case-sensitive.
Turns off the default data compression algorithms used by most
Disable Data
modems. The field has a blank field of 6 characters as default. The AT
Compression
commands that control this are supported by similar commands;
however, these commands do not operate in the same manner. The
Intel modems require H0%C0 to disable V.42bis & MNP Class 5 data
compression algorithms. The Paradyne products only use %C0 to
disable both algorithms. This field is not case-sensitive.
1-108
Issue 5 October 2002
NOTE:
The Modem Connection: field cannot be set to none if Alarm
Origination is activated.
Table
1-24.
when the modem fields are properly administered.
Enter
Continued on next page
555-233-118