0-65 Personal Menu Password
Range:
200 N/
[0 - 999 N/A]
A*
0-66 Access to Personal Menu w/o Password
Option:
[0] *
Full access
[1]
Read only
[2]
No access
If par.0-61
Access to Main Menu w/o Password
Clock Settings, 0-7*
Set the time and date of the internal clock. The internal clock can be used for e.g. Timed Actions, energy log,
Trend Analysis, date/time stamps on alarms, Logged data and Preventive Maintenance.
It is possible to program the clock for Daylight Saving Time / summertime, weekly working days/non-working
days including 20 exceptions (holidays etc.). Although the clock settings can be set via the keypad, they can also
be set along with timed actions and preventative maintenance functions using the Trane Drive Utility software
tool.
Note
The frequency converter has no back up of the clock function and the set date/time will reset to default
(2000-01-01 00:00) after a power down unless a Real Time Clock module with back up is installed. If no module
with back up is installed, it is recommended the clock function is only used if the frequency converter is inte-
grated into the BMS using serial communications, with the BMS maintaining synchronization of control
equipment clock times. In par.0-79
set properly, e.g. after a power down.
Note
If mounting an Analog I/O MCB 109 option card, a battery back-up of the date and time is included.
0-70 Date and Time
Range:
0 N/A*
[0 - 0 N/A]
0-71 Date Format
Option:
[0] *
YYYY-MM-DD
[1] *
DD-MM-YYYY
[2]
MM/DD/YYYY
0-72 Time Format
Option:
[0] *
24 h
[1]
12 h
TR200 Programming Guide
Function:
Define the password for access to the My Personal Menu via the [Quick
Menu] key. If par.0-66
Access to Personal Menu w/o Password
Full access
[0], this parameter will be ignored.
Function:
Disables password defined in par.0-65
Prevents unauthorized editing of My Personal Menu parameters.
Prevents unauthorized viewing and editing of My Personal Menu pa-
rameters.
Full access
is set to
Clock Fault
it is possible to program for a Warning in case clock has not been
Function:
Sets the date and time of the internal clock. The format to be used is set
in par.0-71
Date Format
Function:
Sets the date format to be used in the keypad.
Function:
Sets the time format to be used in the keypad.
Parameter Description
Personal Menu
[0], this parameter will be ignored.
and par.0-72
Time
Format.
is set to
Password.
55