Parameter Description
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto Reset Trip
[43]
OK Key
[44]
Reset Key
[45]
Left Key
[46]
Right Key
[47]
Up Key
[48]
Down Key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
13-02 Stop Event
Option:
[0] *
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
138
This event is TRUE if the frequency converter is stopped or coasted by
any means (either via digital input, fieldbus or other).
This event is TRUE if the frequency converter is tripped (but not trip-
locked) and the reset button is pressed.
This event is TRUE if the frequency converter is tripped (but not trip-
locked) and an Automatic Reset is issued.
This event is TRUE if the OK key on the keypad is pressed.
This event is TRUE if the Reset key on the keypad is pressed.
This event is TRUE if the Left key on the keypad is pressed.
This event is TRUE if the Right key on the keypad is pressed.
This event is TRUE if the Up key on the keypad is pressed.
This event is TRUE if the Down key on the keypad is pressed.
Use the result of comparator 4 in the logic rule.
Use the result of comparator 5 in the logic rule.
Use the result of logic rule 4 in the logic rule.
Use the result of logic rule 5 in the logic rule.
Function:
Select the boolean (TRUE or FALSE) input to deactivate Smart Logic
Control.
Enters the fixed value of FALSE in the logic rule.
Enters the fixed value TRUE in the logic rule.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
TR200 Programming Guide