Fc Closed Loop - Trane TR200 Series Programming Manual

Hide thumbs Also See for TR200 Series:
Table of Contents

Advertisement

Parameter Lists

20-** FC Closed Loop

Par. No.
Parameter description
#
20-0* Feedback
20-00
Feedback 1 Source
20-01
Feedback 1 Conversion
20-02
Feedback 1 Source Unit
20-03
Feedback 2 Source
20-04
Feedback 2 Conversion
20-05
Feedback 2 Source Unit
20-06
Feedback 3 Source
20-07
Feedback 3 Conversion
20-08
Feedback 3 Source Unit
20-12
Reference/Feedback Unit
20-13
Minimum Reference/Feedb.
20-14
Maximum Reference/Feedb.
20-2* Feedback/Setpoint
20-20
Feedback Function
20-21
Setpoint 1
20-22
Setpoint 2
20-23
Setpoint 3
20-3* Feedback Adv. Conv
20-30
Refrigerant
20-31
User Defined Refrigerant A1
20-32
User Defined Refrigerant A2
20-33
User Defined Refrigerant A3
20-7* PID Autotuning
20-70
Closed Loop Type
20-71
PID Performance
20-72
PID Output Change
20-73
Minimum Feedback Level
20-74
Maximum Feedback Level
20-79
PID Autotuning
20-8* PID Basic Settings
20-81
PID Normal/ Inverse Control
20-82
PID Start Speed [RPM]
20-83
PID Start Speed [Hz]
20-84
On Reference Bandwidth
20-9* PID Controller
20-91
PID Anti Windup
20-93
PID Proportional Gain
20-94
PID Integral Time
20-95
PID Differentiation Time
20-96
PID Diff. Gain Limit
276
Default value
4-set-up
[2] Analog input 54
All set-ups
[0] Linear
All set-ups
null
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
null
All set-ups
[0] No function
All set-ups
[0] Linear
All set-ups
null
All set-ups
null
All set-ups
0.000 ProcessCtrlUnit All set-ups
100.000 ProcessCtrlU-
nit
All set-ups
[3] Minimum
All set-ups
0.000 ProcessCtrlUnit All set-ups
0.000 ProcessCtrlUnit All set-ups
0.000 ProcessCtrlUnit All set-ups
[0] R22
All set-ups
10.0000 N/A
All set-ups
-2250.00 N/A
All set-ups
250.000 N/A
All set-ups
[0] Auto
2 set-ups
[0] Normal
2 set-ups
0.10 N/A
2 set-ups
-999999.000 Proc-
essCtrlUnit
2 set-ups
999999.000 Proc-
essCtrlUnit
2 set-ups
[0] Disabled
All set-ups
[0] Normal
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 %
All set-ups
[1] On
All set-ups
0.50 N/A
All set-ups
20.00 s
All set-ups
0.00 s
All set-ups
5.0 N/A
All set-ups
Change
Conv-
Type
during
er-
opera-
sion
tion
index
TRUE
-
Uint8
FALSE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
FALSE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
FALSE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-3
Int32
TRUE
-3
Int32
TRUE
-
Uint8
TRUE
-3
Int32
TRUE
-3
Int32
TRUE
-3
Int32
TRUE
-
Uint8
TRUE
-4
Uint32
TRUE
-2
Int32
TRUE
-3
Uint32
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-2
Uint16
TRUE
-3
Int32
TRUE
-3
Int32
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
67
Uint16
TRUE
-1
Uint16
TRUE
0
Uint8
TRUE
-
Uint8
TRUE
-2
Uint16
TRUE
-2
Uint32
TRUE
-2
Uint16
TRUE
-1
Uint16
TR200 Programming Guide