Trane TR200 Series Programming Manual page 46

Hide thumbs Also See for TR200 Series:
Table of Contents

Advertisement

[1005]
Readout Transmit Error
Counter
[1006]
Readout Receive Error
Counter
[1007]
Readout Bus Off Counter
[1013]
Warning Parameter
[1115]
LON Warning Word
[1117]
XIF Revision
[1118]
LonWorks Revision
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602] * Reference [%]
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor Current
[1615]
Frequency [%]
[1616]
Torque [Nm]
[1617]
Speed [RPM]
[1618]
Motor Thermal
[1622]
Torque [%]
[1630]
DC Link Voltage
TR200 Programming Guide
View the number of CAN control transmission errors since the last pow-
er-up.
View the number of CAN control receipt errors since the last power-up.
View the number of Bus Off events since the last power-up.
View a DeviceNet-specific warning word. One separate bit is assigned to
every warning.
Shows the LON-specific warnings.
Shows the version of the external interface file of the Neuron C chip on
the LON option.
Shows the software version of the application program of the Neuron C
chip on the LON option.
View the number of running hours of the motor.
View the mains power consumption in kWh.
View the Control Word sent from the frequency converter via the serial
communication port in hex code.
Total reference (sum of digital/analog/preset/bus/freeze ref./catch up and
slow-down) in selected unit.
Total reference (sum of digital/analog/preset/bus/freeze ref./catch up and
slow-down) in percent.
Present status word
View the two-byte word sent with the Status word to the bus Master
reporting the Main Actual Value.
View the user-defined readouts as defined in par.0-30
Unit, par.0-31
Custom Readout Min Value
Max
Value.
Actual power consumed by the motor in kW.
Actual power consumed by the motor in HP.
Voltage supplied to the motor.
Motor frequency, i.e. the output frequency from the frequency converter
in Hz.
Phase current of the motor measured as effective value.
Motor frequency, i.e. the output frequency from the frequency converter
in percent.
Present motor load as a percentage of the rated motor torque.
Motor speed reference. Actual speed will depend on slip compensation
being used (compensation set in par.1-62
used, actual speed will be the value read in the display minus motor slip.
Thermal load on the motor, calculated by the ETR function. See also pa-
rameter group 1-9* Motor Temperature.
Shows the actual torque produced, in percentage.
Intermediate circuit voltage in the frequency converter.
Parameter Description
Custom Readout
and par.0-32
Custom Readout
Slip
Compensation). If not
45