Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
TR200 Programming Guide
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
See parameter group 5-3* for further description.
Use the result of comparator 0 in the logic rule.
Use the result of comparator 1 in the logic rule.
Use the result of comparator 2 in the logic rule.
Use the result of comparator 3 in the logic rule.
Use the result of logic rule 0 in the logic rule.
Use the result of logic rule 1 in the logic rule.
Use the result of logic rule 2 in the logic rule.
Use the result of logic rule 3 in the logic rule.
Use the value of DI18 in the logic rule (High = TRUE).
Use the value of DI19 in the logic rule (High = TRUE).
Use the value of DI27 in the logic rule (High = TRUE).
Use the value of DI29 in the logic rule (High = TRUE).
Use the value of DI32 in the logic rule (High = TRUE).
Use the value of DI33 in the logic rule (High = TRUE).
This event is TRUE if the frequency converter is started by any means
(either via digital input, field bus or other).
Parameter Description
137