Replacing Parts for Maintenance
CAUTION
IMPORTANT
Dispose of discharged fluid properly, in accordance with the laws in effect in your locale.
Discharged fluid is flammable and contains toxic ingredients. Never attempt to incinerate discharged fluid or discard it with
ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams. Doing so may have an adverse impact on the
environment.
8.
Quickly attach the emptied drain bottle to the machine once more.
9.
Open the right cover.
10.
Replace the tray pad.
IMPORTANT
Place the tray pad with an orientation that matches the shape of the wiper tray. If you place the tray pad with the incorrect
orientation, it will not be possible to clean the wiper correctly.
11.
Close the right cover.
12.
Press [ENTER].
The screen shown below appears, and then the machine is filled with TR2 cleaning liquid. The (approximate)
remaining time for the procedure is displayed on the screen. (The display shown below is an example.
"01:45" = "1 minute and 45 seconds")
FILLING LIQUID
>>>>>
If the TR2 cleaning liquid runs out during filling, the screen shown below appears. Replace the TR2 cleaning
liquid pouch. When you replace the wiper cleaning liquid pouch, the display returns to the original screen.
P. 58「TR2 Cleaning Liquid Pouch Replacement」
CHANGE CL-LIQUID
FOR WIPER
When the following screen is displayed again, the wiper tray cleaning is finished.
260
4. Replacing Consumable Parts
Doing so may cause fire.
To store discharged fluid temporarily, place it in the included drain bottle or in a du-
rable sealed container such as a metal can or polyethylene tank, and cap the
container tightly.
Any spillage or vapor leakage may cause fire, odor, or physical distress.