Handling Severe Dot Drop-out and Dot Displacement
EMPTY
DRAIN BOTTLE
CAUTION
IMPORTANT
When you remove the drain bottle, a few drops of discharged fluid may come out of the machine. Exercise caution to prevent
this fluid from soiling your hands or the floor.
10.
Quickly attach the emptied drain bottle to the machine once more.
11.
Press [ENTER].
EMPTY
DRAIN BOTTLE
WARNING
CAUTION
IMPORTANT
Dispose of discharged fluid properly, in accordance with the laws in effect in your locale.
Discharged fluid is flammable and contains toxic ingredients. Never attempt to incinerate discharged fluid or discard it with
ordinary trash. Also, do not dispose of it in sewer systems, rivers, or streams. Doing so may have an adverse impact on the
environment.
The screen shown below appears, and then cleaning starts. The (approximate) remaining time for the proce-
dure is displayed on the screen. (The display shown below is an example. "01:45" = "1 minute and 45 sec-
onds")
CLEANING...
>>
When finished, the screen shown below appears again.
SUPER CL.
AB
12.
Press [MENU] to go back to the original screen.
250
3. Advanced Maintenance
Before you detach the drain bottle, be sure to wait for the screen to display "EMPTY
DRAIN BOTTLE." After discarding the discharged fluid, promptly attach the drain bot-
tle to the machine.
Failing to follow this procedure may cause discharged fluid to flow out of the tube and spill, soiling
your hands or the floor.
Never place discharged fluid or ink near an open flame.
Doing so may cause fire.
To store discharged fluid temporarily, place it in the included drain bottle or in a du-
rable sealed container such as a metal can or polyethylene tank, and cap the con-
tainer tightly.
Any spillage or vapor leakage may cause fire, odor, or physical distress.