5.2.11

CSET instruction (programmable controller CPU monitor)

ZP_CSET
Structured ladder
ZP_CSET
EN
ENO
Un*
d1
s1
d2
s2
Input argument
EN:
Executing condition
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
s1:
Reception channel number
1: Channel 1 (CH1 side)
2: Channel 2 (CH2 side)
s2:
Variable that stores control data
Output argument
ENO:
Execution result
d1:
Dummy
d2:
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
Setting
data
Function
This instruction registers and cancels the programmable controller CPU monitoring.
ST
ENO:=
(EN, Un*, s1, s2, d1, d2);
ZP_CSET
Internal device
R, ZR
*1
Bit
Word
s1
s2
d1
d2
*1: Local devices and file registers per program cannot be used as setting data.
5.2 Serial Communication and Modem Interface Instruction
5.2.11 CSET instruction (programmable controller CPU monitor)
Executing condition :
indicates the following instruction.
ZP_CSET
:Bit
:String
:ANY16
:Array of ANY16 [0..111]
:Bit
:ANY16
:Array of bit [0..1]
J
\
U
\G
Bit
Word
ZP_CSET
ZP_CSET
Sirial
Modem
5
Constant
Zn
Others
K, H
5-89