Cset Instruction (Programmable Controller Cpu Monitor) - Mitsubishi QCPU Structured Programming Manual

Melsec-q series
Hide thumbs Also See for QCPU:
Table of Contents

Advertisement

ZP_CSET
Device
Device code
[13]
S2
[14]
S2
Monitoring start device
[15]
S2
Number of registered points
[16]
S2
[17]
S2
[18]
S2
Programmable
controller CPU
monitoring
setting
[19]
S2
1st
* 1st block
[20]
S2
[21]
S2
Programmable
controller CPU
[22]
monitoring
S2
to
setting
[102]
S2
2nd to 10th
* 2nd to 10th block
5.2 Serial Communication and Modem Interface Instruction
5-72

5.2.11 CSET instruction (programmable controller CPU monitor)

Item
Specify the code of the device to be monitored.
0
Other than 0
Specify the start number of the monitoring device in
this block.
Specify the number of registered points (read points)
of this block.
0
1 or more
* For a bit device, specify the number of points in units
of words.
Specify the monitoring condition of this block.
0
Monitoring condition
1 or more
Specify the monitoring condition value for this block.
Monitoring condition
0 or more: Monitoring condition
value
* Specify '0' at constant cycle transmission.
Specify the start pointer of the table to which the user
frame number for condition agreement transmission
for this block is set.
User frame output start
0
pointer
1 to 100
Specify the number of user frame transmissions
(outputs) for condition agreement transmission for this
block.
Number of user frame
0
transmissions
1 to 100
Specify the data number for modem function
connection when making notification in condition
agreement transmission for this block.
0
Modem connection
data No.
BB8
H
8001
The same item arrangement as the first
programmable controller CPU monitoring setting item.
Setting data
: No device monitored
: Device code
: No device monitored
: Number of registered points
: No specification (at constant
cycle transmission)
: Monitoring condition
: No specification (at constant
cycle transmission and
notification)
: Start pointer
: No specification (at constant
cycle transmission and
notification)
: Number of transmissions
: No specification (at data
transmission and constant
cycle transmission)
to BD5
: Connection data number (flash
H
ROM)
to 801F
: Connection data number
H
H
(buffer memory)
Setting range
Setting side
90
to CC
H
H
(Device code)
0 or more
0, 1 or more
0 to 65535
0 to 000A
,
H
0101
to
H
010A
H
0, 1 to 100
User
0, 1 to 100
0,
BB8
to
H
BD5
,
H
8001
to
H
801F
H

Advertisement

Table of Contents
loading

Table of Contents