Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 631

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

Parts to be replaced
Original intermediate transport
sensor
[E726] Transport/exit signal reception jam
Classification
RADF jam
Check item
RADF board
SYS board
Switching power supply
Parts to be replaced
RADF board
SYS board
Switching power supply
[E731] Stop jam at the original exit/reverse sensor
Classification
RADF jam
Check item
Exit roller
Stop jam at the original exit/
reverse sensor
RADF board
Parts to be replaced
Exit sensor
RADF board
Exit roller
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Transport/exit signal reception jam
Board check
Connector check
Harness check
Board check
Connector check
Harness check
Check if the 24V and 5V outputs of the switching power supply
are normal.
Board check
Connector check
Harness check
Stop jam at the original exit/reverse sensor
Clean the exit roller if it is stained.
Sensor check (Perform the input check: 03-[FAX] ON[7]/[E])
Connector check (J93, CN75)
Harness check
Board check
Connector check (CN75)
Harness check
Replace it if it is worn out.