(5)
Remove the 3 E-rings [1], 2 bushings [2], 2
bearings [3] and 1 gear [4].
Notes:
When installing, check that the bearing
flange is outside the plate.
The pressure roller for the 25/30/35ppm
models and for the 45/50ppm models is
different. The edge of the shaft of the
pressure roller for 45ppm/50ppm is colored
blue for identification.
After a new pressure roller is installed in the
frame of the fuser unit, be sure to remove the
protection sheet attached to the roller to
avoid damaging or staining its surface.