Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 429

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

(5)
When the "Current sensor voltage (V)" in (B) is converged and the "Sensor output control value
(bit value)" corresponding to the value for initial developer material is displayed in (C), the
adjustment is completed.
When the adjustment is completed, the [OK] button is displayed on the screen.
( B )
( C )
( A )
Notes:
The values in (A), (B) and (C) vary with humidity.
(6)
Press the [OK] button to store the adjustment result in the memory.
(7)
Turn the power OFF and install the toner cartridges.
Notes:
When "Waste toner box replacement" is displayed at adjustment, follow the steps below.
<When "Waste toner box replacement" is displayed>
 Basic Manual "[E] Waste toner box replacement"
1.Replace the waste toner box with a new one and close the front cover.
2.Key in [4833] (Recovery from toner empty/waste toner full).
3.Check that "WAIT" is displayed.
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
Y: x.xxV
M: x.xxV C: x.xxV K: x.xxV
Y: yyy
M: yyy
C: yyy
Y: z.zzV
M: z.zzV C: z.zzV K: z.zzV
( B ) : Current sensor voltage ( V )
( C ) : Sensor output control value ( bit value )
( A ) : Target value ( V ) for adjustment reference voltage
Fig.6-5
6 - 3
K: yyy
e-STUDIO2555C/3055C/3555C/4555C/5055C
SETTING / ADJUSTMENT
6

Hide quick links:

Advertisement