[CE00] Punch communication error
Classification
Finisher related service call
MJ-1107 (When MJ-6104 is installed)
Check Item
Hole punch control PC board (HP)
Replacement part
Hole punch control PC board (HP)
Finisher control PC board
MJ-1108 (When MJ-6104 is installed)
Check item
Hole punch control PC board
(HP)
Parts to be replaced
Hole punch control PC board
(HP)
Finisher control PC board
[CF10] Communication module writing failure
Classification
Finisher related service call
Check item
Finisher
LGC board
Parts to be replaced
Finisher control PC board
LGC board
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
Communication error between finisher and punch unit:
Communication error between finisher controller PC board and
punch controller PC board
•
Check the connectors and harnesses between the hole
punch control PC board (HP) and the finisher control PC
board.
•
Board check
Measures
•
Check the connectors and harnesses between the hole punch
control PC board (HP) and the finisher control PC board.
•
Board check
Remark
Communication module writing failure.
•
Check if the harness connecting the equipment and the finisher
controller PC board is disconnected or open circuited.
•
Check if the conductor pattern on the finisher controller PC
board is open circuited or short circuited.
•
Update the finisher firmware.
•
Check if the harness connecting the finisher and the LGC board
on the equipment is disconnected or open circuited.
•
Connector check (CN363)
•
Check if the conductor pattern on the LGC board is open
circuited or short circuited.
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved