Check item
Setting
[F106_6]/[F106_7]/[F106_8]/[F106_10] /[F106_UNDEF] ADI-HDD error: Error caused by reason
other than F106_0 to 5 errors
Classification
Other service call
Check item
Setting
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
Perform [3]+[C]+[POWER]-> [3.Format HDD], and then
install the system software by performing
[4]+[9]+[POWER]-> [4.System Software(HD data)].
Notes:
The following items will be deleted by performing
[3]+[C]+[POWER]-> [3.Format HDD].
Message Log
Job Log
Spool Data (Print, Email reception)
Template
In case this error occurred after returning SRAM data for
SRAM cloning:
Copy the ADI-HDD encryption key from FROM to
SRAM.
1. Start the equipment in the 3C mode: [3] + [C] +
[POWER]
2. The authentication menu is displayed. Press [OK]. (Not
required in the default setting)
3. Select "5. Key Backup Restore" and then press the
[START] button.
4. Select "6. ADIKey FROM to SRAM" and then press the
[START] button.
5. After the restoring of the encryption key has completed,
"Operation Complete" is displayed.
6. After the operation has completed, shut down the
equipment by pressing the [POWER] button.
ADI-HDD error: Error caused by reason other than F106_0 to 5
errors
Perform [3]+[C]+[POWER]-> [3.Format HDD], and then
install the system software by performing
[4]+[9]+[POWER]-> [4.System Software(HD data)].
Notes:
The following items will be deleted by performing
[3]+[C]+[POWER]-> [3.Format HDD].
Message Log
Job Log
Spool Data (Print, Email reception)
Template
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
8 - 224
Measures
Error item
Measures