[CE41] Image quality TRC control test pattern abnormality
Classification
Image control related service call
Step
Check item
1
Change the setting of the
image quality TRC control to
"Disabled". Set the values of
08-2600 and 08-8103 to "0".
2
Output several number of
sheets of the image quality
control test pattern (04-270)
and the list print
([9][START]->101), and
check the pattern of each
color. Is the image normal?
3
Change the setting of the
image quality TRC control to
"Enabled". Set the values of
08-2600 and 08-8103 to "1".
4
Perform the automatic
gamma adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 5.
5
4.Check if the harness
between the connector
CN128 on the SYS board
and the connector CN350 on
the LGC board is
disconnected or open
circuited. Correct if so.
6
6.Check if the conductor
patterns on the SYS board
and the LGC board are short
circuited or open circuited.
7
7.If no abnormality is found
in steps 5 to 6 above,
replace the IMG board.
8
8.Perform automatic gamma
adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 9.
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
The image quality TRC control test pattern is not printed
normally.
Result
YES
NO
•
Check if process units and developer units
are properly installed.
•
Check if there is any scattered toner or
developer material around the LED head,
clean it if there is any.
•
Correct the problem by referring to
"Troubleshooting for the Image".
P. 8-277 "8.5 Troubleshooting for the
Image"
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
8 - 196
Error item
Measures
Next
step
2
3
4
6
7
8