[CE41] Image quality TRC control test pattern abnormality
Classification
Image control related service call
Step
Check item
1
Change the setting of the
image quality TRC control to
"Disabled". Set the values of
08-2600 and 08-8103 to "0".
2
Output several number of
sheets of the image quality
control test pattern (04-270)
and the list print
([9][START]->101), and
check the pattern of each
color. Is the image normal?
3
Change the setting of the
image quality TRC control to
"Enabled". Set the values of
08-2600 and 08-8103 to "1".
4
Perform the automatic
gamma adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 5.
5
4.Check if the harness
between the connector
CN128 on the SYS board
and the connector CN350 on
the LGC board is
disconnected or open
circuited. Correct if so.
6
6.Check if the conductor
patterns on the SYS board
and the LGC board are short
circuited or open circuited.
7
7.If no abnormality is found
in steps 5 to 6 above,
replace the IMG board.
8
8.Perform automatic gamma
adjustment. If the
adjustment is normally
finished, this is the end of
the procedure. If the error
CE41 still occurs, proceed to
step 9.
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
The image quality TRC control test pattern is not printed
normally.
Result
YES
NO
Check if process units and developer units
are properly installed.
Check if there is any scattered toner or
developer material around the LED head,
clean it if there is any.
Correct the problem by referring to
"Troubleshooting for the Image".
 P. 8-277 "8.5 Troubleshooting for the
Image"
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
8 - 196
Error item
Measures
Next
step
2
3
4
6
7
8