Download Print this page

Toshiba e-STUDIO 2555C Service Manual page 828

Multifunctional digital color systems
Hide thumbs Also See for e-STUDIO 2555C:

Advertisement

[8122] Domain - Invalid Username or Password
Classification
Network error
Check item
Setting
[8123] Domain - Server not present in Network
Classification
Network error
Check item
Setting
[8124] Domain - User account is disabled on Server
Classification
Network error
Check item
Setting
[8125] Domain - User account has expired and cannot be used for logon
Classification
Network error
Check item
Setting
[8126] Domain - User account is locked and cannot be used for logon
Classification
Network error
Check item
Setting
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
The user name or password of the domain authentication is
not valid and the user cannot log on.
Check if the user name or password is correctly entered.
Enter them by specifying the upper and lower case letters
correctly.
The server cannot be detected at domain authentication.
Check if the server fails. Check the network settings of the
equipment. If name resolution is used, check the settings of
the DNS and DDNS.
The user account is invalid at domain authentication and it
cannot be used to log on.
Check if the setting of the user account in "Active Directory
User and Computer" is disabled.
The user account has expired at domain authentication and it
cannot be used to log on.
Check if the setting of the user account in "Active Directory
User and Computer" has expired.
The user account is locked at domain authentication and it
cannot be used to log on.
Check the setting of the account lock-out on the server.
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
8 - 272
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures

Hide quick links: