[D] Image location of secondary scanning direction
While pressing [0] and [5] simultaneously, turn the power ON. → (Adjustment Mode)
(1)
(2)
Place Test Chart No. TCC-1/TCC-2 on the original glass (with the arrow positioned at the left rear
side).
Press [FAX] → [START] to make a copy at the mode of A4/LT, 100%, Full color and Text/Photo.
(3)
(4)
Measure the distance D from the top paper edge to the 10 mm line of top grid pattern on the copy
with a ruler.
(5)
Check if the distance D is within 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat step 3. to 5. above.
<Procedure>
(Adjustment Mode) → (Key in the code [3031]) → [START]
→ (Key in a value (acceptable values: 67 to 189))
→ [OK] or [INTERRUPT] (Stored in memory)
* The larger the adjustment value is, the longer the distance D becomes (approx. 0.08 mm/
step).