Output Signal Checks - Ikegami Editcam 3 DNS-33W Operation Manual

Table of Contents

Advertisement

Auto Iris Sensitivity Adjustment Trimmer
Operation of VTR Button and RET Button
When Adaptor is Used
When a multi-cable adaptor is used, the return video which is
sent to the camera from the extender can be switched
between RET-1 and RET-2 by pressing the VTR button and
RET button on the zoom lens. This returning operation is set
by the "RET CH SEL SW" of the camera menu "OTHERS".
Refer to "5.10.12 OTHERS (Selecting other operation
modes)", " RET CH SEL SW".
Selection Mode
RET/VTR mode
Pressing the RET button will select
RET-1, and pressing the VTR button
will select RET-2.
RET+VTR mode
Pressing the VTR button while pressing
and holding the RET button will shift
between RET-1 and RET-2.
Notice
• The REC button on the handle works the same as
the VTR button on the lens.
• The RET button on the handle works the same as
the RET button on the lens.
• By pressing the VTR button during operation with
the camera alone, recording is started or stopped.
By pressing the RET button, REC-REVIEW
operation is started.
Operation
RET Button
VTR Button
DNS-33W 0503 VOL1 (E)
4.5.2 How to Use the B3 Mount Lens
AUTO IRIS Operation
If the iris operation is too slow or, on the contrary, too fast
and causes hunting problems in the AUTO IRIS mode, set
the auto iris sensitivity adjustment trimmer of the lens using
the following procedures:
1. Shoot the gray scale chart with the camera.
2. Remove the rubber cap (with an indication such as "Sens.
IRIS GAIN" on it) of the grip on the front side of the
lens, and identify the auto iris sensitivity adjustment
trimmer.
3. Using a Phillips screwdriver, rotate the auto iris
sensitivity adjustment trimmer fully clockwise as viewed
from the front of the lens to set the sensitivity to
maximum.
4. If hunting occurs, adjust the trimmer by gradually
reducing the sensitivity until the hunting problem is
corrected.
5. Make sure that hunting will not occur even when
changing the gain or covering the lens front with the
hand.
If hunting occurs, reduce the sensitivity until the problem
is corrected. Also, if the iris moves slightly with the
flickering light source such as a fluorescent lamp, reduce
the sensitivity until the iris becomes stable.

4.6 Output Signal Checks

After turning ON the power, ensure that the PM and WFM
signals are correctly output. If the signals are not output,
check the following points first before concluding that there
is a failure.
Are the cables connected without errors?
Are the switches correctly set?
Is there a blown fuse?
Is the POWER switch set to ON?
4.6.1 Color-Bar Signal Check
Set the OUTPUT SELECT switch located on the right side of
the camera to "BARS" and ensure that a normal color-bar
signal is output.
4.6.2 Video Signal Check with Chart etc.
Set the OUTPUT SELECT switch to "CAM". Then, shoot the
grey scale chart etc. and ensure that the image is displayed
on the monitor.