4.5 Output Signal Check

After turning ON the power, ensure that signals are correctly output on the PM and WFM. If the signals are not output for some
reason, check the following before concluding that there is a failure.
- Are the cables properly connected ?
- Are the switches correctly set ?
- Is the breaker thrown ?
- Is the POWER switch set to ON ?
Reference:
See "3. INSTALLATION and CONNECTION" for connection of peripheral equipment.

Color-Bar Signal Check

1
Set the BARS button on the OCP or MCP to ON.
Ensure that a normal color-bar signal is output.
To output color-bar signals to the monitor system, operate the MONITOR SELECT button.
MCP
BARS button
"ON"
OCP
CAM PWR VF PWR
OFF
STANDARD
CAP
TALLY
INFO
OPE
I
O
BARS button
"ON"
SCENE FILE
1
2
3
5
6
7
GAIN
PED / FLARE
LENS EXT
FULL
KNOB
FREE
HEAD POWER
RANGE
OPT
HEAD
CCU
CABLE
CLS OPEN
OPEN
SHORT
ALARM
CALL
Note:
When no color bar signal is not displayed on the SDTV signal while you use MCP-200 and press the "Y" button of the MONITOR
SELECT buttons, refer to the operation manual for MCP-200.
O C P - 2 0 0
PM IND
PANEL
/ PAGE
ENABLE
BARS
CAL
AWB
ABB
AWB
ABB
SETUP
MAINTE
USER WFM/PM
S
M
U
W
MIX
R
G
B
Y
SEQ
SUP
FLARE
4
SHIFT
NEXT
CONT
8
KNEE PT
SLOPE
DTL
GAMMA
M FLARE
AUTO
MONITOR SELECT button
RELATIVE
IRIS
SENS
WFM/PM
±1 ±2
R
G
B
Y
PREVIEW
PED
LCD panel
HDK-790GX 1403 VER1 (U)
MONITOR
SELECT button
"Y"
Super
/Mix
"ENC" button
ENC
SEQ
4.5 Output Signal Check
[SDTV]
PM
100%
80%
60%
40%
20%
0%
-20%
WFM
[ HDTV ]
PM
100%
80%
60%
40%
20%
0%
-20%
WFM
55
4

Advertisement

Table of Contents
loading

Table of Contents