Group 9
Error no. Error message
1307
Ink delivery is faulty.
Please check pump and all
connections.
1312
Leakage in hydraulic has
been found. Please check
immediately.
5030
Stroke-Go error
5050
Print-Go distance error
5051
Print-Go error
Release R1.03e
Disturbances/Trouble shooting
Reason of failure
Main pump could not place
the membrane to the central
position within 2,5 sec. dur-
ing the normal operation.
Air in the system.
Leakage.
Bleeding
valve
close correctly.
Main pump is defect elec-
trically.
Main pump is defect mech-
anically.
Leakage sensor at the ca-
binet bottom reports liquid.
During a stroke has been
generated, the next stroke
output
has
been
initiated.
The printing distance (PG-
distance) which is specified
in the job editor between
two prints is smaller than
the print.
During
a
print
PrintGo-signal
has
already received.
Workaround
Activate function perma-
nent bleeding for some
minutes.
Check for leakage
Check bleeding valve and
if necessary replace it.
does
not
Check main pump and if
necessary replace it.
Check system for liquid
and repair.
Check leakage sensor for
dirt and if necessary clean
it.
Reduce production speed.
Increase font width.
already
Use other printing mode
(high speed mode).
Reduce
height
printing
amount of dots).
Reduce font width.
Increase the PG-distance
value.
the
next
Reduce font width.
been
Check
(sensor).
Check signal encoder for
multi-identification
a print.
Enlarge product distance.