Printgo-Gate - Leibinger JET3 User Manual

Hide thumbs Also See for JET3:
Table of Contents

Advertisement

Group 8
8.5.1.6 PrintGo-Gate (Print start query)
A further print start query option is available with this function. If the function is
activated the print process happens only as long as the enquired sensor is active.
The sensor which is required for the PG-gate has to be connected to the interface
X5 of the LEIBINGER JET3 also.
Example: Endless print of tubes with interruptions between the end of the previous
tube and the beginning of the following tube.
Figure 108
Activating options:
High-Level active:
Low-Level active:
Release R1.03e
Gate
PG signals
Gate
PG signals
Job editor
PrintGo-Gate (Print start query)
Page 174
Signals are
disabled and not
carried out!