Group 8

8.5 Parameter settings

You will find further information regarding the calling of the several
submenus and the processing of settings in the chapter Parameter
setting tools!
8.5.1 Print parameter
In the menu <Print Parameter > you can commit the kind of text output, select the
PrintGo source and you can activate or deactivate the monitoring functions.
The following settings can be carried out:
PrintGo-Delay
PrintGo-Distance
PrintGo-Repeat
PrintGo-Holdoff Distance
8.5.1.1 PrintGo-delay
The setting allows the delay of the text output by the entered value. The input
happens in the measurement which has been selected in the basic settings.
The set value is shown on the accordant display field.
As higher the entered value, as later starts the print.
Figure 103
Release R1.03e
Job editor
Drop Flighttime
Selection of PrintGo Source
Selection of function PrintGo-Gate
Selection monitoring functions
Print delay
PG signal
Page 169
Text (beginning)
PrintGo-delay