8.5.1.8 Drop flighttime

The setting causes a temporal change of the drop charging. The input happens in
µsec.
The set value is shown on the accordant display field.
High speed changes require the drop flying time compensation to prevent deviations
of the text positions. Condition is the setting of a higher print delay because the
drop charging has to start earlier for higher speed.
This function is only necessary if the printing is carried out at very slow but also
very fast processing speeds; that means if the speed differences are very high.
Figure 110
8.5.2 Encoder parameter
The LEIBINGER JET3 composes the printed lines of single dots and therefore it
requires a signal encoder (encoder) which tranfers when the single dot lines (so
called strokes) should be printed.
Explanation:
This encoder is also called StrokeGo-source. The required signal can be generated
internally as well as externally.
In the menu <Encoder Parameter> you can carry out the basic settings of the
signal encoder.
The following settings can be carried out depending on the encoder signal source:
Selection of encoder signal source
Internal speed
Lock backward on/off
Release R1.03e
Job editor
Example:
Setting of drop flighttime
A stroke is a complete dot line
in vertical direction (dot height).
Rotating direction
Resolution