Group 5

5.3.2 Grounding (Potential equalization)

Specially for countries without existing protected earth connection, there is a
special grounding point located at the side of the printer.
This threaded socket must be connected to ground if there is no ground pin in the
mains socket/plug.
The threaded case is sealed inwards and thus IP 65 conform. With a screw and a
ring terminal (cable lug) the grounding can be fixed easily.
Please note, that the grounding point (7) is hidden behind the round
grounding-symbol-label (6) on the lower left hand side of the cabinet
of the printer.
Grounding instructions
A separate grounding line (min. cable cross-section 2,00 mm
cabinet must be installed before the print head is mounted in the installation and
before the printer is plugged to the power supply.
The connection must be carried with a solid bonding that corresponds with
existing guidelines.
Annotation: A suitable grounding cable is available optionally (accessories).
The installation (machine) and the printer must have the same potential/ground.
Release R1.03e
Transport/Start up
Grounding (Potential equalization)!
In case of a non existing grounding or that the grounding of the
printer is not carried out properly, this could cause serious injury or
death and it can also cause malfunctions or damages at the printer!
These dangers or demolitions can happen for example because of
electrostatic discharge (ESD) or potential difference.
The printer must be always be switched off and the mains plug
must be always unplugged if you plug and/or unplug any
connectors!
Page 30
2
) to the printer
LEIBINGER JET3