Group 7

7.4.5.2 Save log file

The recorded machine relevant data of the last 72 hours of operation can be saved
on an external memory device (USB-stick or SD-CARD).
Figure 56
or
2
Save log file
1 – USB-connection
2 – SD-Card Slot
3 – Button <Export>
4 – Message <Export is running...>
Proceeding:
Plug an USB-stick or a SD-card device in the USB-connection (1) on the back of
the printer.
or
Insert a SD-card in the slot (2) on the controller board in the electronic cabinet.
Press the button <Export> (3).
Now the data are saved on the connected medium and the message <Export is
running...> (4) is displayed during the process.
Release R1.03e
Data/Programming
1
3
5 – Message <Log file saved>
6 – Button <OK>
7 – Message <Insert storage medium>
8 – Schaltfläche <OK>