Group 5
Basic data /Recommended working conditions:
Signal
All signals
Increment Counter/
Reset Counter
Power ON
Jobselect 0-9
Input 0-5
In the following table you will find the minimum pulse widths which are required to
release the assigned function at the X4 plug.
Function
Open nozzle
Close nozzle
Print start
Print stop
Turn off printer
Mirrored horizontally
Gauger synchronization signal
The function allocations of the inputs 0 up to 5 happens by the
software of the JET3 in the menu Settings
You will find a circuit diagram of the interface in the appendix of this
manual!
(1)
All 24V inputs which are designated with (1) are protected by a self-reset fuse with 700 mA.
(2)
For a change of the Jobselect inputs it has to be carried out within the duration of bounce,
that means only after termination of this period of time the new Jobselect No. is validated.
Release R1.03e
Transport/Start up
Parameter
Input level High
Input level Low
Input resistance
Minimum pulse width
Minium pulse width
Maximum duration
of bounce
Minimum pulse widths
Minium pulse width
300ms
300ms
500ms
500ms
750ms
200ms
200ms
Value
15 up to 30V
-3,5V up to 3,5V (or high
resistance)
6,8kOhm
250µs
2,5 s
(2)
10 ms
Depending on assigned function
(see following table)
I/O-Settings
LEIBINGER JET3
Page 38