green if it doesn't exceed the CBS, yellow if it does exceed the CBS, but not the MBS, and red
otherwise. The srTCM is useful, for example, for ingress policing of a service, where only the length,
not the peak rate, of the burst determines service eligibility.
rate
Syntax
rate cir cir-rate-in-kbps [pir pir-rate-in-kbps]
no rate
Context
config>qos>sap-ingress>meter
Description
This command defines the administrative PIR and CIR parameters for the meter.
The rate command can be executed at anytime, altering the PIR and CIR rates for all meters created through
the association of the SAP Ingress QoS policy with the meter-id.
Note: When the meter mode is configured in trtcm2 mode, the system interprets the PIR rate parameter as
EIR for use by RFC 4115 algorithm.
The no form of the command returns all meters created with the meter-id by association with the QoS policy
to the default PIR and CIR parameters (max, 0).
Default
rate cir 0 pir max — The max default specifies the amount of bandwidth in kilobits per second (thousand
bits per second). The max value is mutually exclusive to the pir-rate value.
Parameters
cir cir-rate-in-kbps — The cir parameter overrides the default administrative CIR used by the meter. When
the rate command has not been executed or the cir parameter is not explicitly specified, the default CIR
(0) is assumed.
Fractional values are not allowed and must be given as a positive integer.
The actual CIR rate is dependent on the meter's adaptation-rule parameters and the hardware.
Values
pir pir-rate-in-kbps — Defines the administrative PIR rate, in kilobits, for the meter. When this command
is executed, a valid PIR setting must be explicitly defined. When the rate command has not been
executed, the default PIR of max is assumed. When the rate command is executed, a PIR setting is
optional.
Fractional values are not allowed and must be given as a positive integer.
The actual PIR rate is dependent on the meter's adaptation-rule parameters and the hardware.
Note: If the meter mode is configured as trtcm2, the system configures the policer's EIR rate, based on
the value of the PIR rate configured by the user.
Values
7210 SAS-X and 7210 SAS-R6 OS Quality of Service Guide
0 — 20000000, max
0 — 20000000, max
Operational Commands